Loading...

Configuring the Load Type for a Decora Smart® Z-Wave Dimmer

Leviton Decora Smart Z-Wave dimmers are compatible with different types of loads. Choosing the correct load type will increase compatibility and provide proper operation.


Incandescent Loads (Default):

  • Enter Programming Mode by holding the top of the paddle for 7 seconds (the Locator LED will turn amber), and then release (the Locator LED will begin to blink amber).
  • Tap the top of the paddle 4 times. The Locator LED will quickly flash green and amber.
  • Tap the top of the paddle 4 times.
    • The Locator LED will flash green and amber 3 times to confirm the selection.

LED Loads:

  • Enter Programming Mode by holding the top of the paddle for 7 seconds (the Locator LED will turn amber), and then release (the Locator LED will begin to blink amber).
  • Tap the top of the paddle 4 times. The Locator LED will quickly flash green and amber.
  • Tap the top of the paddle 5 times.
    • The Locator LED will flash green and red 3 times to confirm the selection.

CFL Loads:

  • Enter Programming Mode by holding the top of the paddle for 7 seconds (the Locator LED will turn amber), and then release (the Locator LED will begin to blink amber).
  • Tap the top of the paddle 4 times. The Locator LED will quickly flash green and amber.
  • Tap the top of the paddle 6 times.
    • The Locator LED will flash red/amber 3 times to confirm the selection.